The short answer
Build the wall from the inside out in this order: stud, mineral wool, foil with every seam taped, a 3/4 in furring strip, then the boards. The foil is the only vapor barrier, and the gap behind the boards lets them dry. For the 5 x 7 ft indoor sauna in the planner the insulation and foil layer comes to $656 of materials, and $702 for the 6 x 7 ft outdoor sauna.
A sauna wall is five layers, and the order matters: wall stud, mineral wool between the studs, foil over the studs with every seam taped, a thin furring strip on each stud, and the boards on the strips. The foil keeps steam out of the wool. The gap behind the boards lets the boards dry between sessions.
This guide takes the layers one at a time. The numbers come from the planner's own materials list for the 5 x 7 ft indoor and 6 x 7 ft outdoor plans, priced at the stores named in the designer. Where a heater maker has a rule, we quote it. Where we are giving you our own build choice, we say so.
The five layers, in order
Work from the framing toward the room. Each step below is one layer, and the designer writes the same list with your own wall sizes.
Wall stud and ceiling joist.
The framing is the cavity you fill. Run the wires for the heater, the lights and the thermostat before anything closes it up, because the foil goes over the top of them.Mineral wool between the studs.
Fill the cavity edge to edge, with no gaps at the corners or around the framing. The planner uses an R-15 batt in indoor walls and R-23 in outdoor walls and in every ceiling.Foil, face in, over the studs.
Staple the roll to the face of the studs and joists with the shiny side toward the room. Overlap each sheet 2 to 3 in and tape every seam and every hole with aluminum foil tape.Furring strips over the foil.
Screw a 1x2 strip through the foil into every stud and every ceiling joist. The strip is 3/4 in thick, and that thickness is the air gap.Boards on the strips.
The cedar or aspen goes on the strips, not on the foil. Leave the gap at the floor and the gap between wall and ceiling boards that your heater's manual asks for.
The table is what the designer lists for the foil layer, so you can see the quantities behind the order above. The wool is the biggest line; the foil, tape and staples are the smaller ones.
| Plan | Item | Quantity | What it covers | Cost |
|---|---|---|---|---|
| 5 x 7 ft indoor | ROCKWOOL Comfortbatt R15, 3.5 x 15.25 x 47 in, 59.7 sq ft per bag, sold by the bag | 3 bags | walls 164 sq ft: 3 bags at 59.7 sq ft each, 5 percent spare; sold by the single bag | $258.00 |
| ROCKWOOL Comfortbatt R23, 5.5 x 15.25 x 47 in, 39.8 sq ft per bag, sold by the bag | 2 bags | ceiling 38 sq ft: 2 bags at 39.8 sq ft each, 5 percent spare; sold by the single bag | $151.32 | |
| ProSaunas Vapor Barrier Foil, 48 in x 80 ft (aluminum-faced kraft, rated over 200 F) | 1 roll | foil face in, laps 2 to 3 in, 232 sq ft with laps | $92.90 | |
| Prosaunas Aluminum Tape, 2 in x 164 ft | 1 roll | every seam and every hole: the laps, the corners and the ceiling line, and all round the door, the three vent sleeves and the heater cable (26 ft of it); about 136 ft of the 164 ft you buy, the rest is left over | $49.99 | |
| Arrow T50 3/8 in. Galvanized Heavy-Duty Staples, 1,250-pack (model 506) | 1 pack | 3/8 in staples for a hammer tacker or staple gun; hold the foil on the studs until the furring goes on | $4.97 | |
| GRK #8 x 2-1/2 in Trim Head Screws, 100-pack | 3 boxs | furring through the foil into the studs and joists, one every 16 in (261 with spares): 2-1/2 in so each screw bites 1-3/4 in into the framing | $46.14 | |
| 1x2 x 8 ft | 34 pcs | F1, F2, F3, F4, F5 (cutting map) | $52.36 | |
| 6 x 7 ft outdoor | ROCKWOOL Comfortbatt R23, 5.5 x 15.25 x 47 in, 39.8 sq ft per bag, sold by the bag | 6 bags | walls 178 sq ft, ceiling 45 sq ft: 6 bags at 39.8 sq ft each, 5 percent spare; sold by the single bag | $453.96 |
| ProSaunas Vapor Barrier Foil, 48 in x 80 ft (aluminum-faced kraft, rated over 200 F) | 1 roll | foil face in, laps 2 to 3 in, 257 sq ft with laps | $92.90 | |
| Prosaunas Aluminum Tape, 2 in x 164 ft | 1 roll | every seam and every hole: the laps, the corners and the ceiling line, and all round the door, the window, the three vent sleeves and the heater cable (35 ft of it); about 155 ft of the 164 ft you buy, the rest is left over | $49.99 | |
| Arrow T50 3/8 in. Galvanized Heavy-Duty Staples, 1,250-pack (model 506) | 1 pack | 3/8 in staples for a hammer tacker or staple gun; hold the foil on the studs until the furring goes on | $4.97 | |
| GRK #8 x 2-1/2 in Trim Head Screws, 100-pack | 3 boxs | furring through the foil into the studs and joists, one every 16 in (263 with spares): 2-1/2 in so each screw bites 1-3/4 in into the framing | $46.14 | |
| 1x2 x 8 ft | 35 pcs | F1, F2, F3, F4, F5 (cutting map) | $53.90 |
Prices are the store prices on the date shown on each line in the designer. Wall quantities include 5 percent spare on the wool and 15 percent on the foil for the laps. Totals before tax and shipping.
What to put between the studs
The planner uses mineral wool, and that is our recommendation: it is a plain stone wool batt, easy to cut to a cavity, and it does not rely on a facing to do its job. HUUM's1 electric heater manual asks for an insulation layer of 50 to 100 mm, about 2 to 4 in, behind the foil, which a 3.5 in R-15 batt fits.
Mineral wool, fiberglass and foam
Mineral wool is the one we build with. Fiberglass batts in the same thickness also fill a cavity, but many come with a paper facing, and the facing is the part to avoid. See the mistakes section for why. If you buy fiberglass, buy it unfaced.
Foam board is the one with a manufacturer line behind it. HUUM's1 manual says foam insulation boards covered with a vapour barrier foil suit well. That is all the manual says on foam, and we do not go past it: the foil on the face is the barrier, and the board does not replace it. Check the maker's temperature rating before you use any board on the wall behind a heater.
How thick, and why the outdoor wall is thicker
HUUM's1 range is for the room it describes. For the indoor plans we use the R-15 batt, 3.5 in, which sits inside that range. For the outdoor cabin and for every ceiling the planner uses R-23, a 5.5 in batt, because a cabin sits in the weather and a ceiling loses the most heat. Those are our choices for sizing the materials list, not a code number. Your local building department can say whether your area asks for a particular R-value on an outbuilding.
Foil, not plastic
The vapor barrier in a sauna is aluminum foil, not polyethylene sheet. The foil in the planner is an aluminum-faced roll sold for saunas and rated over 200 F, and it does two jobs: it stops steam moving into the wool, and it reflects heat back into the room. HUUM's1 manual calls for aluminium foil or another reflective material on top of the insulation, with the joints covered with foil tape.
Putting it up
Shiny side toward the room.
The face that reflects goes in. Run the roll across the studs, pulled flat, and staple at each stud with 3/8 in staples. The staples only hold it until the furring goes on.Overlap 2 to 3 in.
Each new sheet laps the last one. Tape along every lap with aluminum foil tape, pressed down hard with a rag or a squeegee.Tape every hole.
Every staple line, every cut, every place a wire passes through. The tape is cheap, and a taped seam is what makes the foil a barrier instead of a reflector with holes.Wrap the corners.
Run the foil around inside corners in one piece where you can, so the corner is a fold and not a seam. Where two sheets must meet in a corner, tape both edges.Seal around the boxes and vents.
Cut the foil to the opening, fold the edge in toward the box or the sleeve, and tape it all round. The same goes for the ventilation sleeves; the ventilation guide shows where each one sits.
A foil roll and a roll of aluminum foil tape are the two items to buy first. Our recommendation is aluminum foil tape rated for the heat, the kind the foil's maker sells with the roll, not cloth tape.
The air gap behind the boards
The furring strip leaves a 3/4 in gap between the foil and the boards. The gap does two things. It gives the back of the boards air so they can dry after a session. And the foil reflects heat only when there is air in front of it: in a Green Building Advisor thread about foil on a sauna wall, an expert member put it this way, "Without an air gap, a radiant barrier is just a film that does pretty much nothing."
HUUM's1 manual recommends a 10 mm gap, about 3/8 in, between the moisture barrier and the lining board, with spacers. Our 3/4 in strip is wider than that because a 1x2 is the strip a builder already has and it fastens well. If you want to match the manual, use a thinner strip. Either way, keep the gap from being blocked: leave the boards off the floor and leave a gap between wall and ceiling boards, as the HUUM manual does (at least 100 mm off the floor, 5 mm between wall and ceiling board), so the air can move. The build guide has the order of the build.
The ceiling gets the same layers
HUUM1 says to insulate the ceiling in the same way as the walls. In the planner it is R-23 wool, foil, a strip on every joist and then the boards. Heat collects at the ceiling, so skipping it costs more than skipping a wall.
Safety
Do not insulate a chimney in use
HUUM's manual says it is forbidden to insulate flues in use, and to check with the authority for fire safety which parts of a firewall can be insulated. Keep wool and foil away from a stove, a chimney and their clearances. The stove manual sets the distances.
The outdoor cabin
An outdoor sauna has the same inner layers, plus the things a building in the weather needs. The wall is R-23 wool, the foil is face in, and the furring and boards are the same. What changes is the outside of the wall.
Outside the wool
Put a weather barrier outside the sheathing that is vapor open, so any moisture that does get into the wall can leave to the outside. In another Green Building Advisor thread about a sauna wall with foil inside, an expert member said Tyvek is an air barrier that lets vapor through: it blocks rain while the materials behind it can still dry. That is one builder's advice on a forum and a good rule of thumb, not a standard. The wall outside the foil should be open to drying, and the foil inside should be closed.
The floor
For a cabin on joists in a cold climate the designer adds an optional line: cold climates: mineral wool between the floor joists, held from below by the board on the next line, 59 sq ft. It is not in the total, because a warm-climate cabin does not need it. If you add it, hold the wool up with cleats and cover the underside with a vapor-open board so animals cannot get in. Our outdoor sauna guide covers the rest of the cabin.
Common insulation mistakes
Two vapor barriers.
Foil on the inside and a second barrier, such as plastic or a faced batt, buried in the wall holds moisture between them. We build with one: the foil, on the warm side, and a vapor-open layer outside. That is our build choice.Paper facing under the foil.
Many batts come with a kraft paper face. Under the foil that is a second layer that is not rated for sauna heat and that adds a second barrier. We build with unfaced batts so the foil is the only vapor retarder.Foil with open seams.
A foil sheet that is stapled but not taped is a reflector, not a barrier. Tape every lap and every hole.Boards straight on the foil.
No air gap means no drying space behind the boards and a foil that reflects nothing. Put the furring strip on.Foil face out.
The shiny face goes toward the room. Check the roll before you start.Gaps in the wool at corners and boxes.
A cavity that is not filled leaves a cold path. Cut the batt to the space and tuck it in around wires.
Depends on where you build
What the planner does not decide
The planner lists the layers and the quantities. It does not know your climate, your inspector or what your area asks for on the walls of an outbuilding. Check with your local building department, and follow your heater's manual where it differs from this page.
Next: see where the openings go through these layers in the ventilation guide, add up the whole build in the sauna cost calculator, or read the framing and wiring order in the DIY sauna guide.
Sources
Every number in this guide that does not come from our own sauna designer was checked against these 3 documents, numbered in the order the text first cites them and read between Oct 9, 2026 and Oct 29, 2026. 3 are heater makers, codes and stores.
- 1HUUMDROP 2.0 electric heater user manual (EU, v6)
- 2Green Building Advisor Q&AAir gap needed for foil radiant vapor barrier?
- 3Green Building Advisor Q&ATwo (air/vapor) barriers?