Skip to content
Design free

Heater size calculator

Sauna heater size calculator

Enter the inside size and the glass. The calculator works out the room volume the way Harvia asks, glass counted, and picks the heater from our table whose rated range covers it, with the circuit it needs.

Volume, glass and kW

Your room

Heater for this room8 kWDetails

Where

Inside, drawn by the sauna designer

The heater the planner picks

8 kW

Harvia KIP 8 kW, built-in controls, stones, rated for 250 to 425 cu ft

Room volume
294 cu ft
With the glass counted
305 cu ft
Glass
2.7 sq ft
Floor area
42.0 sq ft
Load at 240 V
33.3 A
Conductors at 125%
41.7 A
  • Heater sized to the room: 305 cu ft (window glass added), Harvia 8 kW for 250 to 425
  • Floor area for this heater: 42.0 sq ft

Breaker: 45 A 2-pole typical: a continuous load, so the breaker is also sized at 125 percent (41.7 A, next standard size). Your electrician confirms against the nameplate, the heater manual and local code.

Wire: 8 AWG copper THHN/THWN-2 in conduit with 75 °C terminations; if NM-B cable, 6 AWG. Your licensed electrician confirms the circuit.

Wood-fired instead, outdoor only: Harvia M3 16.5 kW wood stove package: chimney kit, protective bedding, sheath, stones, 16.5 kW, rated for 212 to 459 cu ft. It requires heater-availability confirmation, and it needs its chimney kit and the maker's clearances to everything that burns.

Design this sauna around the heater

The designer places the heater, its guard and the vents, and prices the room.

The rule

Volume first, then the glass.

Room volume is the inside width times the depth times the ceiling height. Glass loses more heat than an insulated wall, so Harvia counts each square meter of glass as 1.2 cubic meters of room. The heater's rated range has to cover the result; past 90 percent of a range, the planner moves up a size. The maker's floor-area table and its clearances to the benches and the ceiling are checked in the designer.

The circuit follows the heater: a continuous load, so the conductors and the breaker are sized at 125 percent of it (NFPA 70, National Electrical Code). Your licensed electrician confirms it.

An electric sauna heater full of stones behind its wooden guardIllustration
The heaters the planner chooses from, with the maker's rated room volume and the price we read
HeaterkWRated roomLoad at 240 VPrice
Harvia KIP 4.5 kW, built-in controls, stones4.5100 to 210 cu ft18.8 A$1,214.00
Harvia KIP 6 kW, built-in controls, stones6170 to 300 cu ft25.0 A$1,254.00
Harvia KIP 8 kW, built-in controls, stones8250 to 425 cu ft33.3 A$1,317.00
Harvia Cilindro Half 9 kW, built-in controls, stones9141 to 494 cu ft37.5 A$1,920.00
Harvia Club K10G 10 kW package (HRKGU1024C Kit): Xenio Wi-Fi control, stones10390 to 600 cu ft41.7 A$3,173.00
Harvia Club K12.5G 12.6 kW package (HRKGU1224C Kit): Xenio Wi-Fi control, stones12.6500 to 750 cu ft52.5 A$3,555.00
Harvia Club K15G 14.8 kW package (HRKGU1524C Kit): Xenio Wi-Fi control, stones14.8630 to 1000 cu ft61.7 A$3,755.00
Scandia Ultra Large 15 kW, 240 V (SN-HEL-15240-60), wall-mounted, 60 minute timer and wall thermostat15up to 1428 cu ft62.5 A$2,853.00
Harvia M3 16.5 kW wood stove package: chimney kit, protective bedding, sheath, stones16.5212 to 459 cu ftWood, no heater circuit$3,292.00
Harvia Pro 20 24 kW wood stove package: chimney kit, protective bedding, sheath, stones24283 to 706 cu ftWood, no heater circuit$3,993.00
Harvia Pro 26 26.6 kW wood stove (WKPR26M), stove only26.6353 to 918 cu ftWood, no heater circuit$2,066.00
Harvia Pro 36 wood stove (WKPR36M), stove only31494 to 1271 cu ftWood, no heater circuit$2,364.00
Harvia Linear 18 Compact 14.3 kW wood stove (WKLI18CPTM), stove only14.3177 to 636 cu ftWood, no heater circuit$1,716.00

Wood stoves are drawn for outdoor cabins only, and each one requires heater-availability confirmation. Prices read at Haven of Heat, 2026-10-09.

Questions

Anything else? Write to us or price the whole sauna.

Questions about heater size

Multiply the inside width, depth and ceiling height to get the room volume in cubic feet, then add the glass: Harvia counts each square meter of glass as 1.2 cubic meters of room. Pick a heater whose rated range covers that number. A 6 x 7 ft room with an 84 in ceiling is 294 cu ft, 305 with its 2.7 sq ft of window glass, and the planner picks the Harvia 8 kW, rated 250 to 425.

Big enough that your room, glass counted, sits inside its rated range, and the planner moves to the next size once a room passes 90 percent of a range. In our table the electric heaters run from 4.5 kW (100 to 210 cu ft) to 15 kW (up to 1428 cu ft). The maker's floor-area table and clearances also have to fit, which the calculator checks.

For the 8 kW heater above: 33.3 A at 240 V, conductors sized at 125 percent (41.7 A), so 8 AWG copper THHN/THWN-2 in conduit with 75 °C terminations; if NM-B cable, 6 AWG. Wire size depends on the heater, the run and the cable type: your licensed electrician confirms it against the nameplate, the heater manual and the code your town adopted.

For the electric heaters in our table, yes: they run on a dedicated 240 V circuit (often called 220), from 18.8 A for the 4.5 kW to 62.5 A for the 15 kW. A wood stove needs no heater circuit, only the light. Your licensed electrician confirms the circuit and the permit.