Heater size calculator
Sauna heater size calculator
Enter the inside size and the glass. The calculator works out the room volume the way Harvia asks, glass counted, and picks the heater from our table whose rated range covers it, with the circuit it needs.
Volume, glass and kW
Your room
Inside, drawn by the sauna designer
The heater the planner picks
Harvia KIP 8 kW, built-in controls, stones, rated for 250 to 425 cu ft
- Room volume
- 294 cu ft
- With the glass counted
- 305 cu ft
- Glass
- 2.7 sq ft
- Floor area
- 42.0 sq ft
- Load at 240 V
- 33.3 A
- Conductors at 125%
- 41.7 A
- Heater sized to the room: 305 cu ft (window glass added), Harvia 8 kW for 250 to 425
- Floor area for this heater: 42.0 sq ft
Breaker: 45 A 2-pole typical: a continuous load, so the breaker is also sized at 125 percent (41.7 A, next standard size). Your electrician confirms against the nameplate, the heater manual and local code.
Wire: 8 AWG copper THHN/THWN-2 in conduit with 75 °C terminations; if NM-B cable, 6 AWG. Your licensed electrician confirms the circuit.
Wood-fired instead, outdoor only: Harvia M3 16.5 kW wood stove package: chimney kit, protective bedding, sheath, stones, 16.5 kW, rated for 212 to 459 cu ft. It requires heater-availability confirmation, and it needs its chimney kit and the maker's clearances to everything that burns.
The designer places the heater, its guard and the vents, and prices the room.
The rule
Volume first, then the glass.
Room volume is the inside width times the depth times the ceiling height. Glass loses more heat than an insulated wall, so Harvia counts each square meter of glass as 1.2 cubic meters of room. The heater's rated range has to cover the result; past 90 percent of a range, the planner moves up a size. The maker's floor-area table and its clearances to the benches and the ceiling are checked in the designer.
The circuit follows the heater: a continuous load, so the conductors and the breaker are sized at 125 percent of it (NFPA 70, National Electrical Code). Your licensed electrician confirms it.

| Heater | kW | Rated room | Load at 240 V | Price |
|---|---|---|---|---|
| Harvia KIP 4.5 kW, built-in controls, stones | 4.5 | 100 to 210 cu ft | 18.8 A | $1,214.00 |
| Harvia KIP 6 kW, built-in controls, stones | 6 | 170 to 300 cu ft | 25.0 A | $1,254.00 |
| Harvia KIP 8 kW, built-in controls, stones | 8 | 250 to 425 cu ft | 33.3 A | $1,317.00 |
| Harvia Cilindro Half 9 kW, built-in controls, stones | 9 | 141 to 494 cu ft | 37.5 A | $1,920.00 |
| Harvia Club K10G 10 kW package (HRKGU1024C Kit): Xenio Wi-Fi control, stones | 10 | 390 to 600 cu ft | 41.7 A | $3,173.00 |
| Harvia Club K12.5G 12.6 kW package (HRKGU1224C Kit): Xenio Wi-Fi control, stones | 12.6 | 500 to 750 cu ft | 52.5 A | $3,555.00 |
| Harvia Club K15G 14.8 kW package (HRKGU1524C Kit): Xenio Wi-Fi control, stones | 14.8 | 630 to 1000 cu ft | 61.7 A | $3,755.00 |
| Scandia Ultra Large 15 kW, 240 V (SN-HEL-15240-60), wall-mounted, 60 minute timer and wall thermostat | 15 | up to 1428 cu ft | 62.5 A | $2,853.00 |
| Harvia M3 16.5 kW wood stove package: chimney kit, protective bedding, sheath, stones | 16.5 | 212 to 459 cu ft | Wood, no heater circuit | $3,292.00 |
| Harvia Pro 20 24 kW wood stove package: chimney kit, protective bedding, sheath, stones | 24 | 283 to 706 cu ft | Wood, no heater circuit | $3,993.00 |
| Harvia Pro 26 26.6 kW wood stove (WKPR26M), stove only | 26.6 | 353 to 918 cu ft | Wood, no heater circuit | $2,066.00 |
| Harvia Pro 36 wood stove (WKPR36M), stove only | 31 | 494 to 1271 cu ft | Wood, no heater circuit | $2,364.00 |
| Harvia Linear 18 Compact 14.3 kW wood stove (WKLI18CPTM), stove only | 14.3 | 177 to 636 cu ft | Wood, no heater circuit | $1,716.00 |
Wood stoves are drawn for outdoor cabins only, and each one requires heater-availability confirmation. Prices read at Haven of Heat, 2026-10-09.
Questions
Anything else? Write to us or price the whole sauna.
Questions about heater size
Multiply the inside width, depth and ceiling height to get the room volume in cubic feet, then add the glass: Harvia counts each square meter of glass as 1.2 cubic meters of room. Pick a heater whose rated range covers that number. A 6 x 7 ft room with an 84 in ceiling is 294 cu ft, 305 with its 2.7 sq ft of window glass, and the planner picks the Harvia 8 kW, rated 250 to 425.
Big enough that your room, glass counted, sits inside its rated range, and the planner moves to the next size once a room passes 90 percent of a range. In our table the electric heaters run from 4.5 kW (100 to 210 cu ft) to 15 kW (up to 1428 cu ft). The maker's floor-area table and clearances also have to fit, which the calculator checks.
For the 8 kW heater above: 33.3 A at 240 V, conductors sized at 125 percent (41.7 A), so 8 AWG copper THHN/THWN-2 in conduit with 75 °C terminations; if NM-B cable, 6 AWG. Wire size depends on the heater, the run and the cable type: your licensed electrician confirms it against the nameplate, the heater manual and the code your town adopted.
For the electric heaters in our table, yes: they run on a dedicated 240 V circuit (often called 220), from 18.8 A for the 4.5 kW to 62.5 A for the 15 kW. A wood stove needs no heater circuit, only the light. Your licensed electrician confirms the circuit and the permit.