The short answer
Count about 24 in of top bench for each person, hang that bench 43 to 51 in below the ceiling, and leave 30 in of open floor in front of the benches. The 6 x 7 ft outdoor sauna in the planner has 3 seats, a 7 ft ceiling and a 294 cu ft room, and the presets run from 2 to 5 seats.
There is no standard sauna size. The size is set by how many people sit on the top bench, and that comes down to one number: about 24 in of bench per person. Harvia's1 design guide gives a seat for one person as usually 60 cm wide. Divide the length of the top bench by 24 in and you have the seats.
The height comes from the bench, not from the room: the top bench hangs 43 to 51 in below the ceiling. Whatever floor is left is where you stand. This guide runs those three rules on every plan in the planner and shows what it does to the room, the ceiling and the heater.
How many people fit
Seats are counted on the top bench only. The lower bench is a step and a place to sit cooler, not a second row of seats. Where the plan has an L-shaped bench, the side leg adds seats along the second wall. The table is generated from the 10 sizes in the free plans, so it moves when the plans do.
| Room inside | Seats | Top bench | Ceiling | Room volume | Heater |
|---|---|---|---|---|---|
| 4 x 5 ft indoor | 2 | 47-1/2 in long | 7 ft | 140 cu ft | 4.5 kW |
| 5 x 5 ft indoor | 2 | 59-1/2 in long | 7 ft | 175 cu ft | 4.5 kW |
| 5 x 6 ft indoor | 2 | 59-1/2 in long | 7 ft | 210 cu ft | 6 kW |
| 5 x 7 ft indoor | 2 | 59-1/2 in long | 7 ft | 245 cu ft | 6 kW |
| 6 x 7 ft indoor | 3 | 71-1/2 in long | 7 ft | 294 cu ft | 8 kW |
| 5 x 7 ft outdoor | 2 | 59-1/2 in long | 7 ft | 245 cu ft | 6 kW |
| 6 x 7 ft outdoor | 3 | 71-1/2 in long | 7 ft | 294 cu ft | 8 kW |
| 7 x 8 ft outdoor | 3 | 83-1/2 in long | 7 ft 2 in | 401 cu ft | 9 kW |
| 8 x 8 ft wood-fired | 5 | 95-1/2 in long | 7 ft | 448 cu ft | Wood stove |
| 7 x 10 ft outdoor | 5 | 83-1/2 in long | 7 ft | 490 cu ft | 10 kW |
Sizes are inside the walls, width by depth. Seats are 24 in of top bench each, counted whole. The heater is the one the planner picks for the room, with glass counted in the volume.
Read the table as a range, not a menu. The 5 x 7 ft indoor room has a top bench 59-1/2 in long, which is 2 seats; the 6 x 7 ft outdoor room gets 71-1/2 in and 3 seats. When the bench cannot get longer, an L bench is the way to add seats without a wider cabin: the 7x10 L-bench turns the top bench around the corner and seats 5.
Seats are also a shoulder-to-shoulder number. If you want room to stretch out, plan on fewer people for the same room, or a longer bench. The 2 person sauna plans and the 4 person sauna plans show each count drawn and priced.
Bench height and depth
Benches are where the room gets its size, because the bench depth plus the floor in front is the depth of the room. The planner builds each bench from slats with gaps between them, so the depth moves in steps rather than landing on a round number. The sauna bench plans show the slats, rails and screws.
Top bench: one level, the whole wall.
In the 6 x 7 ft outdoor plan the top bench is 23-1/2 in deep, runs 71-1/2 in along the wall, and its top sits 38 in off the floor. That is our default depth, a recommendation and not a rule.Two levels: a step and a seat.
Add a lower bench and it sits 18 in below the top one, our default for a comfortable step, with its top at 20 in. In the 5 x 7 ft indoor plan it is 19-1/2 in deep. The lower bench is where a first-timer starts, and where a hot bather cools down without leaving the room.One level only: a foot step.
Skip the lower bench and a top bench that sits high needs a movable foot step, about 16 to 18 in high. The planner puts one on the cut list when the top bench is over 24 in off the floor.An L bench: the second wall.
The top bench turns the corner. In the 7x10 L-bench plan the side leg runs 66-1/2 in, which is why that cabin seats 5 without being wider.
Depth is a trade. A deeper top bench lets you sit with your legs up, and it eats the floor in front. The floor rule is simple: leave 30 in of open floor so you can stand and reach the benches. Under that, the planner warns, and under 24 in it fails the check. In a shallow room the planner narrows the lower bench before it touches the top one.
Ceiling height
Keep the ceiling low. HUUM's2 manual asks for a room 79 to 91 in high and never under 75 in. Every inch above that is air the heater has to warm, and the hot air collects at the top of the room, over your head, not over the bench.
| What sets it | The number | Why |
|---|---|---|
| Room height | 79 to 91 in, never under 75 in | HUUM's manual range for the room |
| Top bench to ceiling | 43 to 51 in | Head in the hot layer, feet off the cool floor |
| Heater top to ceiling | 42 in or more for the 8 kW in the 6 x 7 ft plan | The heater maker's clearance |
Work from the bench down. Set the top bench where you want to sit, and the ceiling falls 43 to 51 in above it. In the 6 x 7 ft plan that is a 7 ft ceiling with the top bench 46 in under it. The presets run from 7 ft to 7 ft 2 in high, as the table shows.
The heater is the other limit. Each model has a minimum distance from the top of the heater to the ceiling, and a few have a minimum room height too. If you want a lower ceiling to save heat, check the heater first; the designer flags the plan when the ceiling is under what the maker asks for.
The heater wall and the door
Check before you cut
The door and the heater share a wall
The heater and its guard want one wall, and the door wants one too. In a narrow room there is not enough front wall for both, so the planner moves the door to the side wall or flags the layout. The bench in front of the heater also stops at the guard. Both changes cost floor or seats, so check them in the designer before you pick a width.
That is why a room that looks big enough on paper can come up one seat short. A bench that runs in front of the heater gets cut back to the guard, and the cut comes off the seats. Try the width a few inches either way in the designer and watch the seat count before you settle on it.
The heater itself is sized to the room's volume, not to its seats. A bigger room needs a bigger heater, and that sets the circuit, as the sauna heater size calculator shows for your own width, depth and height.
Inside size and outside size
Every size on this page is the inside of the room, the part you sit in. The walls come on top of that, and outdoors they are thicker. An outdoor cabin has 2x6 walls; an indoor room has 2x4 walls. Both add the insulation, the foil, the air gap and the boards on the inside.
| Plan | Inside | Outside the walls | Wall build-up each side |
|---|---|---|---|
| 5 x 7 ft indoor | 5 ft x 7 ft | 5 ft 10 in x 7 ft 10 in | 5 in |
| 6 x 7 ft outdoor | 6 ft x 7 ft | 7 ft 2 in x 8 ft 2 in | 7 in |
The roof comes on top of the outside size, because the eaves hang past the walls. Measure your site for the outside number, the footprint and the setbacks, not the inside one. Setbacks and size limits are set by your town, so check with your local building department before you fix the footprint.
Indoors, the outside number is what has to fit in the basement corner or the garage bay. Deduct the wall build-up from the space before you choose the inside size. The DIY sauna guide covers the build and the cost, and the outdoor sauna guide covers the cabin and the power to it.
Find your size
Start from the people. Pick the seats you need, multiply by 24 in for the top bench, and add the heater side for the wall the heater uses. Then set the ceiling from the bench, check the floor in front, and read the heater the designer picks. The sauna floor plans show every layout from above.
Open the 6 x 7 ft outdoor sauna or the 5 x 7 ft indoor sauna in the sauna designer, change the width, the depth and the height, and watch the seats, the checks and the heater change. When a size works, the sauna plans show it with a materials list, and the 7x10 L-bench plan is the one to look at when you need more seats than the cabin is wide.