The short answer
The planner sets a plunge tub on its own gravel and paver pad 24 in from the wall of an outdoor cabin by default, up to 10 ft, and gives the chiller its own 120 V circuit to a GFCI-protected outdoor outlet. The 6 x 7 ft cabin is $8,751. A stock tank setup adds $725 of parts we price, and the chiller ($2,100) is shown apart.
A sauna and a cold plunge in one yard is a layout problem first and a shopping problem second. The tub is heavy, wet and cold, the sauna is hot and electric, and both want a level base, a path between them and power that is safe near water. Our planner has drawn a plunge tub beside an outdoor cabin since 29 October, and this guide shows what it draws, what it prices and what it leaves to you and your electrician.
We plan the build. We do not give advice on how to use a plunge, and we make no claims about what it does for anyone. Everything below is about space, power, weight and money.
The short answer
Put the tub on its own pad.
A filled tub is too heavy for the cabin floor. The planner stands it on the ground on its own pad of pavers over 4 in of compacted gravel, at least 6 in clear of the porch and the skids.Leave a gap to the cabin.
The default is 24 in from the cabin wall to the pad edge, and the designer accepts 0 to 10 ft. Keep at least 12 in, so splashes and ice stay off the siding.Give the chiller its own outlet.
A 120 V circuit to a GFCI-protected outdoor outlet by the pad, never the heater's 2-pole circuit. An electrician installs it.Decide the water rules with your town first.
Whether NEC Article 680 (pools and spas) applies to a plunge with a chiller is for your electrician and inspector, before the outlet goes in and before the tub is filled.
Plunge plan checks from the sauna designer, run on the 6 x 7 ft outdoor cabin with a tub 24 in off the left wall.
Where the plunge goes
The designer places the tub on the left, the right or the front (the door end) of an outdoor cabin and lets you slide the gap. Pick the side that gives the shortest, flattest path from the cabin door to the tub. If you add a porch or a changing room, the tub still stands on its own pad outside it.
Weight decides the pad, not the style of tub. Water weighs 62.4 lb per cubic foot, and the planner works from that. The three tub types it draws come out like this.
| Tub | Water | Weight on the pad | Pad | Pavers |
|---|---|---|---|---|
| Cold plunge barrel | 110 gal, 919 lb | 165 lb per sq ft | 4 ft 8 in x 6 ft 11 in | 24 |
| Oval stock tank, 2 x 4 ft | 88 gal, 734 lb | 103 lb per sq ft | 4 ft x 8 ft 3 in | 21 |
| Chest-style plunge tub with its own chiller | 139 gal, 1,157 lb | 81 lb per sq ft | 4 ft 8 in x 7 ft 4 in | 24 |
Tub sizes are our planning sizes, not one maker's product: measure the tub you buy and redraw the pad if it differs. The plan checks the cabin floor for 50 lb per sq ft and does not check a porch deck for a tub.
Open the cabin with a cold plunge barrel in the sauna designer and change the tub, the side and the gap to watch the pad redraw.
Tub, chiller or ice
The planner draws three setups. A cold plunge barrel and an oval stock tank each use a separate chiller. A chest-style plunge tub comes with its own chiller built in. Ice is another way to cool water, but we do not draw or price it.
The chiller the planner uses is the Penguin Chillers Cold Therapy Chiller, 17 in wide, 15 in long and 13 in high. Per the planner's reading of its page and owner's manual of July 23, 2024, it is outdoor rated for air above 32 F, it has a built-in pump with 3/4 in camlock ports, it wants 12 in of open space all round, and it should be drained and brought in when freezing is forecast. The tub walls matter too: the kit's bulkheads fit walls up to 1/4 in thick, so a thick wooden barrel needs the maker's advice and a sheet steel tank needs measuring before you drill.
Which items are priced and which are not:
| Setup | Priced at store prices | Shown apart, a range or an allowance |
|---|---|---|
| Barrel | $207 | Cold plunge barrel: $2,299 to $4,000; Penguin Chillers Cold Therapy Chiller: $2,100 |
| Stock tank | $725 | Penguin Chillers Cold Therapy Chiller: $2,100 |
| Chest tub | $159 | Chest-style plunge tub with its own chiller: $2,495 to $3,900 |
Priced lines for the stock tank setup, each with its store and the day we read it: Tarter 2 ft x 2 ft x 4 ft Galvanized Steel Oval Ultra 100 Gal. Stock Tank (model WT224) $334.00 (Home Depot, Hamilton Mill, 2026-10-29); Apollo 3/4 in. Brass Insert Poly Ball Valve $29.96 (Home Depot, Hamilton Mill, 2026-11-18); Everbilt 3/4 in. to 1-3/4 in. Stainless Steel Hose Clamp $18.48 (Home Depot, Hamilton Mill, 2026-11-17); 100 Gallon Oval Stock Tank Hard Insulated Cover (ASIN B0CY796YGX) $199.99 (Amazon.com, 2026-10-29); 3/4 in crushed stone base $27.50 (US average, delivered, 2026-10-27); Pavestone 16 in. x 16 in. x 1.75 in. Yukon Square Concrete Step Stone (model 72650) $114.87 (Home Depot, Hamilton Mill, 2026-10-29). Apart: the tub ranges and the chiller are estimates or allowances, shown next to the total and not in it.
Limit
Why the tub and chiller are not in the total
Tub makers differ in size, wood and insulation, and we did not read those product pages as a price. We show them as a range next to the total instead of burying a guess in it. Measure the tub you buy against the pad.
Power, GFCI and drain
The cabin's heater and the chiller are separate loads. Harvia's2 KIP manual says to connect the heater to a standard 2-pole breaker and not to use a GFCI breaker, so the plan keeps the chiller on its own 120 V circuit. The chiller draws 3.9 A by the planner's reading of its manual, and the manual sets the breaker size.
Outdoor outlets at a home are GFCI protected under NEC1 210.8. One secondary summary, written to the 2020 edition, puts it as item (F): outdoor outlets on single-phase circuits of 150 V to ground or less and 50 A or less. The list changes with the edition your town adopted, so your electrician confirms it. The outlet the planner draws by the pad is provisional for a second reason: if your inspector decides Article 680 applies, the receptacle distance from the water, the bonding of the tub and metal parts and the chiller's listing follow that article, and the outlet moves.
Safety
Water, electricity and a licensed electrician
A tub of water next to an outdoor outlet is a place for a licensed electrician, not a DIY wire. The planner makes the outlet and the Article 680 question a hold point: the electrician and the inspector settle both before the outlet goes in and before the tub is filled. Where the water may be drained, frost under the pad, and a fence or locking cover are for your building department.
The water path in the plan runs from a low bulkhead at the tub's drain end, through a ball valve and the filters to the chiller, and back through a bulkhead just above the water line. The valves are our choice, so the filters can be cleaned without draining the tub. The chiller sits within about 3 ft of the tub's drain, with its base level with or below the tub's base, because its pump is not self-priming. For the circuit sizes of the sauna heater itself, see the sauna electrical guide.
For the stock tank setup, these are the checks the plan runs on the plunge. The first 2 have a pass or fail; the others are hold points and notes for you and your electrician.
| Check | Status | What the plan says |
|---|---|---|
| Cold plunge on its own pad | Passes | About 88 gal in the stock tank weighs about 734 lb (103 lb per sq ft under the tub, before the tub and the bathers), on its own 4 ft x 8 ft 3 in pad of pavers over 4 in of compacted gravel, clear of the cabin's deck blocks |
| Cold plunge distance from the cabin | Passes | 24 in from the left wall to the edge of the pad |
| Cold plunge tub | Note or hold point | Oval stock tank, 2 x 4 ft, drawn as 48 in x 24 in and 24 in tall, filled to about 21 in (88 gal), with the Penguin Chillers Cold Therapy Chiller beside it, drawn 17 in x 15 in |
| Chiller, outdoor rated, and its water path | Note or hold point | Penguin Chillers Cold Therapy Chiller: outdoor rated for air above 32 F, built-in pump, 3/4 in camlock inlet and outlet, 17 in W x 15 in L x 13 in H, 120 V, 3.9 A, on the pad 12 in from the stock tank with 12 in of pad all round, its base level with the tub's base. Water path: the low bulkhead at the tub's drain end, a ball valve, the inline filter (arrow toward the chiller) and the kit's 150 micron filter, the chiller inlet, its pump, the outlet, a ball valve, and back through a bulkhead just above the water line. The kit's bulkheads fit tub walls up to 1/4 in thick: the stock tank is sheet steel; measure it before you drill |
| Chiller circuit | Note or hold point | The chiller gets its own 120 V circuit to a GFCI-protected outdoor outlet with an in-use cover, by the pad; it never shares the heater's 2-pole circuit |
| Cold plunge under NEC Article 680: inspector decides first (hold point) | Note or hold point | Not decided in this plan: whether NEC Article 680 (pools, spas and hot tubs) or a local pool rule applies to a cold plunge with a chiller. The outlet drawn by the pad is provisional; where the water may be drained, frost under the pad, and a fence or a locking cover are also for your building department |
Winter changes the plan. The chiller is outdoor rated for air above 32 F, so in a freezing climate you drain it and bring it in. An insulated hard cover goes with the tub, and the plan adds a note that a lockable strap is worth having if children are around.
The base for both
Two bases, two jobs. The cabin sits on skids over deck blocks, each block on a gravel pad, as the sauna foundation guide explains. The plunge sits on its own pad of 16 in square pavers over 4 in of compacted gravel, which the planner prices at 0.5 cu yd of gravel and 21 pavers for the stock tank. The plan keeps the two clear of each other, so the tub's pad stands apart from the cabin's deck blocks.
Add stepping pavers for the path from the cabin door to the tub, since the plan's pad count does not include a path. The outdoor sauna plans list every cabin size the plunge can sit beside.
Cost of the pair
The 6 x 7 ft outdoor cabin with its default window is $8,751 in materials and heater at the store prices we read, before the electrician, freight and tax. The plunge adds to that:
| Setup | Cabin | Plunge parts we price | Together | Still apart |
|---|---|---|---|---|
| Barrel | $8,751 | $207 | $8,958 | Cold plunge barrel, Penguin Chillers Cold Therapy Chiller |
| Stock tank | $8,751 | $725 | $9,476 | Penguin Chillers Cold Therapy Chiller |
| Chest tub | $8,751 | $159 | $8,910 | Chest-style plunge tub with its own chiller |
Read the table as a floor, not a quote. The tub is the biggest unknown: for a barrel-style tub the plan's own range is $2,299 to $4,000 for the tub alone, and a chest tub with its chiller built in is $2,495 to $3,900. The stock tank is the one setup where the tub itself is a store price, $334.
Add the tub and the chiller from the last column to get the real figure, and a path of pavers. The sauna cost calculator totals the rest as you change the size.
Sources
Every number in this guide that does not come from our own sauna designer was checked against these 3 documents, numbered in the order the text first cites them and read between Oct 9, 2026 and Nov 20, 2026. 3 are heater makers, codes and stores.
- 1NFPA 70, National Electrical CodeArticle 424.4(B), branch-circuit sizing for fixed electric space-heating equipment (2020 text)
- 2HarviaKIP heaters (KIP-30/45/60/80, B1 240 V): Instructions for installation and use, manual Y05-1516 B (08/26), the one edition this plan follows
- 3GFCI.com, after NFPA 70 section 210.8Where the NEC requires GFCI, dwelling units (written to the 2020 edition)